7 Reviews
|
Average Customer Review
Share your thoughts with other customers
Create your own review
|
|
Most Helpful First | Newest First
|
|
9 of 9 people found the following review helpful:
4.0 out of 5 stars
Venting Kit,
By
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
This is an excellent kit for any unit that will be vented horizontally that does not exceed 18 inches from the outside of your house. In other words, you need to be mounting the water heater against the outside wall of your home for this kit to work. If you are mounting your unit against such a wall and the wall is less than 18 inches in thickness, this is a perfect kit and will have everything you need. The only downside is that the kit does not do a good job of telling you how to install the required wall heat shield. A quick call to the company can provide you with the help you will need to install it.
3 of 3 people found the following review helpful:
4.0 out of 5 stars
UL listed kit for adjacent side wall installation,
Amazon Verified Purchase(What's this?)
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
One clarification for the manufacturer description:the two itemized gear clamps are for flex inlet tubing; Z-VENT stainless exhaust sections include all necessary built-in gear clamps. J. D. Weekley was misled by his authorized installation professional: 1) The only aluminum in the kit is flex inlet tubing. Bosch specifies aluminum, PVC or galvanized for inlets. 2) 3 or 4 inch stainless category III exhaust can be used, but 3 is a better fit. 4 inch requires a 3-to-4 inch increaser. Bosch specifies a 3 ft minimum exhaust length; using 4 inch might increase that minimum. Another consideration is that 3 inch diameter is less likely to require damaging webs when run thru cinder block walls. The thru-wall vents provided for exhaust are not long enough for cinder blocks; an additional 6-inch length of Z-VENT will be needed. One consideration not addressed by this kit is condensate disposal when a drain is not within reach of the drain tube supplied with the heater. For whatever reason, parts slide together so that leading edges of inner pipes are facing exhaust gas flow, contrary to conventional flue pipes.
4.0 out of 5 stars
got the jobe done,
By
Amazon Verified Purchase(What's this?)
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
This is a great product that makes your work easier. Make sure you make holes in wall first and install it then mount your hot water heater. Manafacturer could have put some extra pieces more in package for the price they charge
5.0 out of 5 stars
Highly recommend it,
By
Amazon Verified Purchase(What's this?)
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
This is one of the best water heater.I am sure other "Tankless" water heater would be equally good.
4.0 out of 5 stars
Expensive!,
By Captin Burrito (At table) - See all my reviews
Amazon Verified Purchase(What's this?)
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
You need it for proper installation - but the cost is way too much for what it is - not Amazon's fault - Bosch's fault.
5.0 out of 5 stars
A *must* when installing the Bosch Aquastar gas tankless water heater,
By
Amazon Verified Purchase(What's this?)
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
This kit worked perfectly with my Bosch Aquastar water heater. It made installation easier and safer.
1 of 3 people found the following review helpful:
2.0 out of 5 stars
Not Appropriate for Most Installations,
This review is from: Bosch AquaStar Horizontal Vent Terminator #AQ3 (Tools & Home Improvement)
I had the authorized Bosch Aquastar installation professional survey my home for installaion of this water heater. He took one look at the AQ3 and said it wasn't appropriate. For one thing, Bosch mandates that the exhaust be constructed of 4" stainless steel. This equipment is 3" and the main exhaust vent pipe is aluminum. In some climates, the fumes react with moisture in the air and form acid (think acid rain). The acid and water accumulate in this corrugated pipe and drip back into the unit. This means that the main vent will fail, and then cause the water heater to fail.Unless you live in the high desert, don't use this installation kit. I'm returning mine. |
|