Qty:1

Other Sellers on Amazon
Add to Cart
$303.30
+ Free Shipping
Sold by: Test Equipment Depot
Have one to sell? Sell on Amazon

Image Unavailable

Image not available for
Color:
  • Hanna Instruments HI 8936CLN Conductivity Transmitter with LCD, 0 to 1,999 microsiemens/cm, 1 microsiemens/cm Resolution
  • Sorry, this item is not available in
  • Image not available
  • To view this video download Flash Player
      

Hanna Instruments HI 8936CLN Conductivity Transmitter with LCD, 0 to 1,999 microsiemens/cm, 1 microsiemens/cm Resolution


List Price: $337.00
Price: $310.03 & FREE Shipping. Details
You Save: $26.97 (8%)
Only 4 left in stock (more on the way).
Ships from and sold by Amazon.com.
2 new from $303.30

Specifications for this item
Brand Name Hanna Instruments
Part Number HI8936CLN
Number of Items 1
Display LCD
Measurement Type Electrical Conductivity
UNSPSC Code 41115609

The Hanna Instruments HI 8936CLN conductivity transmitter with LCD screen i... Read full product description



Product Features

  • Conductivity transmitter attaches directly to an inline four-ring probe and a controller for constant offsite monitoring of conductivity
  • For use with the HI 7635, HI 7638, or HI 3001 conductivity probe and an HI 8931 controller (sold separately)
  • LCD screen displays measurement values for ease of calibration, process monitoring, and verification
  • Direct connection to transmitter probe provides a positive electrical connection to eliminate signal loss over long distances
  • Automatic temperature compensation (ATC) is performed with circuitry in the transmitter and a built-in temperature sensor on the probe

Product Details

  • Product Dimensions: 50 x 50 x 50 inches
  • Shipping Weight: 2 pounds (View shipping rates and policies)
  • Domestic Shipping: Currently, item can be shipped only within the U.S. and to APO/FPO addresses. For APO/FPO shipments, please check with the manufacturer regarding warranty and support issues.
  • International Shipping: This item is not eligible for international shipping. Learn More
  • ASIN: B0085WZ758
  • Item model number: HI8936CLN
  • Amazon Best Sellers Rank: #704,515 in Industrial & Scientific (See Top 100 in Industrial & Scientific)
  • Manufacturer’s warranty can be requested from customer service. Click here to make a request to customer service.

     Would you like to give feedback on images?


Product Description

The Hanna Instruments HI 8936CLN conductivity transmitter with LCD screen is designed for use with the HI 7635, HI 7638, or HI 3001 platinum conductivity potentiometric probe and an HI 8931 controller (all sold separately), for constant offsite monitoring of conductivity. An LCD screen displays measurement values for ease of calibration, process monitoring, and verification. Direct connection of the transmitter to the probe provides a positive electrical connection that eliminates signal loss over long distances. Circuitry in the transmitter and a built-in temperature sensor on the probe provide automatic temperature compensation (ATC). The transmitter has a range of 0 to 1,999 microsiemens/cm, and can be wall-mounted at any convenient location close to the measurement site. The transmitter requires external power to the 4 to 20mA current loop. Protecting the transmitter inside a case is recommended to minimize thermal drifts, particularly for outdoor measurements.

Specifications
Conductivity (EC) range0 to 1999μS/cm
Accuracy range at 20 degrees C/68 degrees F+ or - 2% of full scale (excluding probe error)
CalibrationManual, 2 point, with offset and slope trimmers
Conductivity probeHI 7635 for in-line applications (not included)
Recorder output4 to 20mA, not isolated, max 500 ohm
Temperature compensationFixed or automatic, 0 to 50 degrees C (32 to 122 degrees F) with Β=2%/degrees C
Protection ratingIP 65
Environment0 to 50 degrees C/32 to 122 degrees F
Weight1kg/2.2lb.
Dimensions165 x 110 x 71mm/6.5 x 4.3 x 2.8 inches (H x W x D)

H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.

Conductivity meters, also known as electrical conductivity (EC) meters, measure the ability of a solution or material to conduct an electrical current. This measurement helps determine if the solution is, for example, contaminated or contains too much saline. In general, pure solutions, such as distilled water, have low conductivity. More saline- or nutrient-rich solutions, such as seawater or fertilizers, have high conductivity. Conductivity measurements are often used with total dissolved solids (TDS) measurements, which are typically expressed in ppm (parts per million). TDS consist of dissolved minerals and salts. To determine the amount of TDS, conductivity is measured, and the result is converted to a TDS measurement. Different meters provide results for conductivity, TDS, or both, and the application determines meter selection. Conductivity meters are used in research laboratories and a variety of industries, such as water-quality testing, waste-water treatment, hydroponics, agriculture, aquaculture, and cosmetics manufacturing.

Hanna Instruments manufactures analytical instrumentation and supplies, including pH meters, electrodes, chemical reagents, and buffer solutions. The company, founded in 1978 and headquartered in Woonsocket, RI, meets International Organization for Standardization (ISO) standard 9001.

What's in the Box?

  • HI 8936CLN conductivity transmitter
  • Instructions

Customer Questions & Answers

Customer Reviews

There are no customer reviews yet.
5 star
4 star
3 star
2 star
1 star
Share your thoughts with other customers