The KN-COSM-IB combines a Carbon Monoxide and Ionization Smoke Alarm, providing two important safety devices in a single unit. This alarm includes a voice warning system that helps eliminate confusion, as it tells you if its detected fire or carbon monoxide, or even if it needs a new battery. This alarm has 9 volt battery backup, which protects you and your family - even during a power outage when many incidences occur. The alarm also allows you to easily silence nuisance alarms using its convenient Smart Hush feature. This talking combo alarm is powered by your home’s electricity and can interconnect with other smoke alarms in your home. Experts recommend interconnected alarms, because when one sounds, they all sound, providing an early warning against fire by dramatically increasing your ability to hear an alarm anywhere in your home, regardless of where the fire starts.
![]() | |||
|
|
|
![]() Provides the recommended protection of an interconnected system. When one alarm goes off, they all do. View larger. |
![]() Provides the recommended protection of an interconnected system. When one alarm goes off, they all do. View larger. |
Combination Smoke/CO Alarm for Improved Safety
The Kidde Combination Carbon Monoxide & Smoke Alarm includes a voice warning system that eliminates confusion and clearly warns you and your family of a smoke or carbon monoxide danger, or if your battery is in need of replacement or your alarm is in hush mode.
Alarm Warnings
Fire: The red LED will flash and be accompanied by three long alarm beeps followed by a verbal warning message “Fire! Fire!” The alarm will repeat pattern until smoke is eliminated.
Carbon Monoxide: Four short alarm beeps followed by a verbal warning “Warning! Carbon Monoxide!” This continues until the unit is reset or CO is eliminated.
Low Battery: One chirp followed by warning “Low Battery” The red LED light will flash. This pattern will continue every minute for the first hour. After the first hour the red LED light will flash once every minute accompanied by the chirp sound. The low battery warning will only sound once every fifteen minutes.
Voice Hush Indication: “Hush Activated” and “Hush Cancelled” voice announcement
Peak Level Memory: If the alarm had detected a CO level of 100ppm or higher when the Test/Reset button is pressed, the unit will announce “Carbon Monoxide Previously Detected” to warn of the CO incident.
Inter-connectable for Improved Safety
Fire and consumer experts recommend interconnected alarms for added protection. According to the National Fire Protection Association (NFPA), most Americans feel they are more at risk of being a victim of a tornado than of a house fire. Actually the opposite is true. Fires are more common than any other disaster that strikes a family at home, and can become deadly in minutes.
You have on average less than three minutes from the time you hear a smoke alarm to escape a fire. The sooner you hear an alarm, the sooner you can get out safely. Smoke alarms that link together so that when one goes off, they all go off, are called interconnected alarms. These alarms provide more warnings in more places, giving your family more time to escape a house fire. Houses built after 1993 are required by building codes to have interconnected alarms that are wired into their electrical system.
Trademarked Hush Feature for Convenience
By pressing the Hush button, you can easily and safely silence nuisance alarms caused by non-emergency situations, such as overcooked dinners.
This feature desensitizes the alarm for approximately ten minutes. If the smoke is not too dense, the alarm will silence immediately, the unit will verbally announce “Hush Mode Activated,” and the green LED will flash every 2 seconds for approximately 10 minutes.
Reliable 9-Volt Battery Backup, Indicator LED, Test Feature, Low Battery and End-of-Life Warning
The alarm’s 9-volt battery backup provides continuous protection, even during power outages. Because this alarm only helps protect you if it's working, this unit features a red LED that flashes every 30 to 40 seconds to indicate that it is operating correctly. For additional peace of mind, the alarm also contains a test/reset button that enables you to periodically test its circuitry and horn.
If any form of battery failure is detected the red LED light will flash and the unit will “chirp” one time, followed by the warning message “Low Battery.” This cycle will occur once every minute, and will continue for at least seven days.
Seven (7) years after initial power up, this unit will “chirp”every 30 seconds. This is an “operational end of life” feature which will indicate that it is time to replace the alarm. UL 2034, the independent standard applicable to CO alarms, requires CO alarms to have an end of life warning. This requirement went into effect in March 2007, meaning any CO alarm manufactured after April 2007 with a UL listing must have this feature. Most states that require CO alarms in residential dwellings mandate that the alarm meet the UL 2034 standard.
The unit measures just 5.75 inches in diameter and 1.7 inches deep, and it features a neutral, white finish. It includes tamper resist features to deter vandalism or theft. This combination smoke/CO alarm is UL listed, so you can be confident of its quality, and it is backed by a 5-year limited warranty.
About Kidde: A UTC Fire & Security Brand
Renowned for global leadership in fire detection and suppression, Kidde provides solutions ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems. Kidde is a UTC Fire & Security brand, with a history that’s rich with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's first wireless networked smoke detectors in 2004.
What's in the Box
Combination smoke and carbon monoxide alarm with mounting bracket and mounting hardware, quick-connect wiring harness, one 9 volt battery, a 5-year limited warranty and a bilingual (English/Spanish) user's manual.
Product Details
Would you like to update product info or give feedback on images?
|
|
Share your thoughts with other customers:
|
||||||||||||||||||||||
|
Most Helpful Customer Reviews
83 of 85 people found the following review helpful:
1.0 out of 5 stars
How Do I HATE These...Let me count the ways!,
This review is from: Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable (Tools & Home Improvement)
Purchased five of these for use in our personal home with the intent to buy more for rentals if they performed well. Really liked the idea of having a voice warning that tells what the problem is and was thrilled at how easy the installation was...for about 48 hours.
About two days after initially installation, started getting a "beep" but no voice indication of low battery/other. We always keep spare batteries in stock so decided to replace the batteries with fresh ones and problem seemed to go away. Temporarily. A few days later the alert goes off again which of course, signals ALL of them to go off as they are interconnected. This time it indicates a dead battery. Odd since we replaced them but figured our batteries may have been older than we realized. Went to the store and bought all new batteries - replaced in all five units. A few nights later - about 2 in the morning - we get a full fledged alert with the 'WARNING -FIRE!" screeching through the house. After peeling ourselves off the ceiling, we took down the one main culprit and figured that one may be a lemon. Since we have five in the house, we still felt it may be an isolated problem...EXCEPT The Next night we get yet another screeching alert...."WARNING - Carbon Monoxide". It should be worth mentioning to note that we had NO fireplace burning and do NOT cook or heat with anything other than electricity. In fact, nothing was running whatsoever. At this point, we're exhausted from several nights of interrupted sleep and all of these are going back. The good news is the interconnected portion works. The bad news is the constant false alarms will leave you likely to take them down in order to get a full nights sleep. In all our years of smoke alarms these have given more false alerts in just a couple weeks than the past 20 years combined. SKIP~!
36 of 37 people found the following review helpful:
5.0 out of 5 stars
Peace of mind,
Amazon Verified Purchase(What's this?)
This review is from: Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable (Tools & Home Improvement)
For those concerned about previous mfr date issues with reviews, my units were manufactured within 45 days of my purchase date -- which is actually extremely reasonable. I'm guessing that wherever these are manufactured, they are taking a boat trip at least once before hitting a warehouse to wait for me to purchase.
I recently replaced my 10 year old BRK detectors around my entire house. I installed the Kidde PI2000 dual sensor detector in each beadroom and a Kidde KN-COSM-IB smoke and carbon dioxide detector in the hallways in the basement, first and second floor hallways. I researched first alert, brk, and kidde, mostly because I could see them at my local big box hardware store. I chose Kidde becuase it had more features for the wired-in detectors than both first alert and brk. First alert appears to have focused their current lines on battery only units and wireless communications. Brk also had limited options in dual sensors or combo CO detectors in a wired setting. Since neither first alert or brk could supply both a photo sensor/ion wired unit AND a dual CO and smoke wired detector that communicated together, I chose kidde detectors. I wanted them all to communicate and mixing and matching product vendors makes communications between the units impossible. There are no pretty dual detectors that exist on the market. These are nice and boring and don't draw attention. They have a working hush button. That's a new feature that I appreciate. I haven't ripped one of these off the ceiling once yet to get them to stop their alarms. I've never done a smoke or CO test. I'll let the experts run those tests. My only tests are using the test button. But it works as identified and is loud. The voice alarms in the COSM unit is good for the hallways and will supplement the normal alarm well. Children are reported to respond faster to "Fire!, Fire!". I've been know to sleep through my daughter's baby monitor on one of her bad nights... There's no way I'm not going to hear both the voice and the piercing alarms DIY info: Since I was replacing an existing AC wired solution, I wanted to continue to have the security of both AC power and battery backup. The best feature by far of this wired in solution is that all detectors are wired to communicate together. If my basement CO detector goes off, then the other two CO detectors also sound with an alarm and a voice indicator. When any of the smoke detectors trip, all detectors sound, and the hallway units voice alert "Fire!, Fire!". This connection between detectors will ensure that I know in the middle of the night if I have a fire in the basement... My house is well soundproofed between floors. In replacing the existing brk wired in units with the Kidde detectors, I had to remove the existing collars and wired in "tails" since the existing ones were not compatible with the Kiddes. You can buy an adapter to convert from the BRK style of tail to the Kidde, but I considered that a waste of money. In my house, all of the smoke detectors are on the same electrical circuit and rewiring the tails and installing the detectors was a matter of ensuring the circuit was off, removeing 3 wire nuts, removing the existing tail, then twisting the new tail into the existing leads and putting the wire nuts back on. less than 3 minutes of work. THe collar was easy to replace. A cordless screwdriver to loosen (not remove) the 2 J-box screws, twist and pull the brk collar off, add the Kidde collar, then tighten the screws. All in all less than 5 minutes per detector... replaceing 7 detectors took less than an hour of work and I made sure to test each one for communications with the other units. For the single detector that I have close to the peak of a cathedral ceiling I replaced the nice alkaline 9v that shipped with the PI2000 with an Ultralife Lithium 9v... they are made specifically for smoke detectors and are claimed to at least double the lifespan of a alkaline up to 10 years.... I'll let you know in ten years if its true. In any case I don't expect to have to change that high detector's battery for years now. Remember that smoke detectors have to be replaced every 10 years.. units that detect CO will have to be replaced after 5yrs... its a chemical based sensor.
45 of 48 people found the following review helpful:
5.0 out of 5 stars
Great Replacement for Smoke Detector,
This review is from: Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable (Tools & Home Improvement)
Replaced a 10 year old BRK Smoke Detector...This Kidde is Great! Hookup took less than 5 minutes, just replaced old pigtail connector, with the included Kidde connectors. The Kidde base feels more sturdy and the sure-lock twist design guaranteed a perfect fit. The Kids love the "voice" warnings (test mode) for Fire & Carbon Monoxide...I also love the visible 120v power indication (green light). Did I mention that Amazon.com has the best price on this unit...yeah, pick one up!